Elmo ExtrIQ line Guía de instalación Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 73
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
Hornet and Bee Installation Guide Technical Specifications
MAN-HRBEIG (Ver. 1.3)
www.elmomc.com
71
4.8. Communications
Specification Details
RS-232 Signals:
RxD , TxD , Gnd
Full duplex, serial communication for setup and control.
Baud Rate of 9,600 to 57,600 bit/sec.
CANopen CAN bus Signals:
CAN_H, CAN_L, CAN_GND
Maximum Baud Rate of 1 Mbit/sec.
Version:
DS 301 V4.01
Layer Setting Service and Protocol Support:
DS 305
Device Profile (drive and motion control):
DS 402
4.9. Pulse-Width Modulation (PWM)
Feature Details
PWM resolution 12-bit
PWM switching frequency on the load 2/Ts (factory default 22 kHz on the motor)
Vista de pagina 70