Example of Connection with Alarm Devices
LOOP THROUGH
Control Equipment
Lights, etc
Connection with Sensor
A sensor can be connected to the terminal block on the back as input from alarm signal. Use no-voltage,
normally open output type
Terminal Specification
Input / Output
Terminal
Input / Output Terminal Circuit Signal Specification
Alarm input
VCC (+3.3V)
10kΩ
Alarm Input
GND
LVC245
TTL negative logic, or
no-voltage, normally
open output
Pulse width; over 100ms
Alarm output
Maximum of DC24V
Under 20mA
Alarm Output
GND
GND